Atmos- Diaphragm gas meter / two-pipe 250 mm connection distance
The ATMOS diaphragm gas meter can be used for custody transfer metering of natural gas and all non-aggressive gases and complies with the requirements of DIN EN1359:2017 and OIML R137-1&2:2012 standards. The diaphragm stroke is not limited by a fixed stop (cantilever principle) and thus enables stable measuring processes and high reliability.
The products shown here may not be available in your region due to legal regulations or specific requirements. Please contact us at export@zennergas.it or vertrieb@zenner.com to find out more about our products and their availability.
Information
Atmos- Diaphragm gas meter / two-pipe 250 mm connection distance
Downloads
Performance characteristics in overview
- Mechanical index: 5 pre-decimal + 3 decimal places
- Mechanical measuring principle: Cantilever principle
- Applied meter standards: DIN EN 1359: 2006 + 2017
- Backflow preventer: Standard
- Remote readout: Retrofittable with communication adapter
- Approved according to MID: Module B & D
- Approved according to DVGW: DG-4701DN0652
- Body/housing: Galvanized steel powder-coated
Applications
The ATMOS diaphragm gas meter is designed for custody transfer metering of natural gas and all other non-aggressive gases in accordance with DVGW worksheet G260 (A) dated September 2021, except for 5. gas family
Other ZENNER products
Discover other interesting products in our product range.